failure mode
FM-21: 離合器過早鬆開或喺鑽孔模式打滑
FM-22
诊断概览
FM-22
可能根本原因
- Numbered setting is too low for the fastener
- Collar is between detents or drill mode is not fully aligned
- Bit, fastener, or material is causing abnormal resistance
- Clutch spring, cam, gear, or drive interface is worn or broken
快速检查
- The clutch releases only at the selected driving torque and stays engaged in drill mode, or the early-release fault is proven.
维修预览
- Increase the numbered setting gradually for driving, or retest once in fully aligned drill mode without forcing the tool.
- If it still releases too early at suitable settings or slips in drill mode, route the clutch and gearbox to service.
- Release the trigger at early ratcheting, remove the battery, and verify the collar is fully aligned with a detent or drill mode.
- Fit a sound correct bit, secure suitable scrap material, and choose range 1 for driving or the proper range for drilling.
这是完整维修手册中所含故障排除指南的预览。
相关症状
The collar moves normally, but the clutch ratchets before a suitable fastener reaches normal depth at appropriate settings, or it audibly slips when drill mode is correctly selected.
The collar moves normally, but the clutch ratchets before a 1. Release the trigger at early ratcheting, remove the battery, and verify the collar is
包含在完整手册中
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views