failure mode
FM-02: BATTERY가 충전기에 완전히 미끄러지거나 장착되지 않음
FM-02 BATTERY가 충전기에 완전히 삽입되거나 장착되지 않음
진단 개요
FM-02 BATTERY가 충전기에 완전히 삽입되거나 장착되지 않음
예상 근본 원인
- Battery family is not compatible with DCB115
- Battery is reversed or misaligned on the rails
- Dry nonconductive debris obstructs a rail or stop
- Pack rail or retention feature is deformed
- Charger rail or cavity geometry is damaged
빠른 점검
- A sound compatible pack slides straight to the fully seated and retained position without force, or the faulty complete item is identified and removed from service.
수리 미리보기
- Confirm a genuine compatible pack and correct orientation, then remove only dry nonconductive debris with a soft nonmetallic brush.
- 6 Slide rails and mechanical stop Align the pack to the seated position without force.
이것은 전체 수리 매뉴얼에 포함된 문제 해결 안내의 미리보기입니다.
관련 증상
The battery stops before the fully seated position and the charger cannot begin a normal charge. No visible charger crack, conductive debris, or swollen pack has yet been confirmed.
yet been confirmed. and the charger for cracked rails; use FM-17 or FM-18 if found.