failure mode
FM-06: MOTORは動作するがブレードが回転しない
FM-06 MOTORは動作するがブレードが回転しない問題。
診断の概要
FM-06 MOTORは動作するがブレードが回転しない問題。
考えられる根本原因
- Blade bolt or outer washer is loose or assembled wrong
- Blade is not seated on the spindle
- Blade bolt or washer is damaged
- Gear train or spindle has stripped or broken
- Spindle lock damage is interfering with the drive
簡単チェック
- The securely mounted blade follows the spindle immediately and runs without slipping.
修理プレビュー
- Inspect blade seating, rotation direction, outer washer, and the left-hand blade bolt; engage the spindle lock only while stopped and tighten the bolt counterclockwise.
- With the battery removed, rotate the blade gently by hand and verify the spindle turns with it without clamp slip, grinding, or abnormal free play.
- If the motor runs but the correctly clamped spindle or blade still does not drive, stop testing and have the gear train, spindle, and lock serviced.
- Release the trigger, wait for all motion to stop, remove the battery, and do not run the saw again until the blade drive is checked.
これは完全修理マニュアルに含まれているトラブルシューティングガイダンスのプレビューです。
関連する症状
Motorは回るがブレードは動かない
Motorは回るがブレードは動かない ブレードクランプ、ギア、スピンドル駆動の故障;FM-06を使用。
motorは動作音がするが、ブレードは動かず、遅れて始動するか滑り、motorを追従しない。
motorが動作している音は聞こえますが、ブレードは動かず、遅れて始動するか、motorの追従ではなく滑っています。1. トリガーを離し、すべての動きが止まるまで待ち、batteryを取り外し、ブレード駆動が確認されるまでノコギリを再度動かさないでください。