failure mode
FM-23: BIT MELUNCUR ATAU TERLEPAS DARI CHUCK
FM-23
Diagnostic overview
FM-23
Likely Root Causes
- Bit was not inserted straight or enough jaw length was not engaged
- Chuck was not tightened firmly by hand
- Bit shank is oily, undersized, worn, or damaged
- Chuck jaws or internal scroll are worn despite normal movement
Quick Checks
- A sound bit remains centered and retained through a moderate test, or chuck wear is proven.
Repair Preview
- Tighten the single-sleeve chuck firmly by hand using the spindle lock, then pull-test the bit before power.
- Make one moderate controlled work test; if a sound correctly tightened bit still slips, route the chuck for service or supported replacement.
- Release the trigger, remove the battery, and remove or catch the loose bit before it can fall.
- Clean the bit shank and chuck jaws dry, reject a bent or damaged bit, and insert a sound bit straight with all three jaws centered.
This is a preview of the troubleshooting guidance included in the full repair manual.
Common Fixes
- Bit bor
Related symptoms
Rahang chuck membuka dan menutup normal, tetapi bit lurus yang kompatibel berputar atau tertarik keluar selama pengeboran atau penggerudian sedang.
Rahang chuck terbuka dan tertutup normal, tapi sebuah bit lurus 1. Lepaskan pemicu, lepaskan battery, dan lepaskan atau tangkap bit yang longgar sebelum
Included in the full manual
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views
- post-repair checks