failure mode
FM-01: AUCUN INDICATEUR NI RÉPONSE DE CHARGE AVEC UNE BATTERIE INSÉRÉE
FM-01 AUCUNE RÉPONSE D'INDICATEUR OU DE CHARGE AVEC UN PACK INSÉRÉ
Aperçu diagnostique
FM-01 AUCUNE RÉPONSE D'INDICATEUR OU DE CHARGE AVEC UN PACK INSÉRÉ
Causes probables
- Outlet is dead, switched off, or unsuitable
- Plug or cord is loose, stressed, or damaged
- Battery is not actually seated or contacts are dirty
- Battery pack is faulty or outside temperature limits
- Internal charger power or control fault
Vérifications rapides
- A fully seated known-good pack starts a normal red-blinking charge, or the persistent charger failure is conclusively routed to authorized service or replacement.
Aperçu de réparation
- Let the pack reach room temperature, dry-clean only the external rails and contacts, and insert it fully until retained.
- Test a second known-good compatible pack in the DCB115 and, when available, test the original pack in a known-good compatible charger.
- Prove the wall outlet with a known-good lamp or appliance, then plug the charger directly into the correct outlet without a questionable strip or extension.
- If the DCB115 remains dark with a proven outlet and known-good pack, stop owner work and have the complete charger serviced or replaced.
Ceci est un aperçu des conseils de dépannage inclus dans le manuel de réparation complet.
Inclus dans le manuel complet
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views
- post-repair checks
Les pages publiques n'affichent qu'un aperçu. Achetez le manuel complet pour télécharger les étapes de réparation, schémas et procédures de vérification complets.