FM-19: VÒNG ĐIỀU CHỈNH CHẾ ĐỘ/MÔ-MEN KHÔNG XOAY HOẶC CĂN CHỈNH ĐƯỢC
FM-19
Tổng quan chẩn đoán
FM-19
Nguyên nhân gốc có thể
- Debris or impact damage blocks the collar
- Collar shell or detent ring is cracked or displaced
- Internal clutch spring or adjustment mechanism is jammed
- Housing or gearbox alignment is damaged
Kiểm tra nhanh
- The collar moves and holds each selected position, or the adjustment mechanism is routed to service.
Xem trước sửa chữa
- Turn the collar gently through the numbered settings and drill mode, confirming distinct stable detents without forcing it.
- If it remains stuck, skips positions, or cannot hold alignment, route the collar and internal clutch mechanism to service.
- Remove the battery before turning or inspecting the mode/torque collar.
- Dry-clean the collar seam and inspect the collar, index mark, and front housing for cracks or looseness.
Đây là bản xem trước hướng dẫn khắc phục sự cố trong sách hướng dẫn sửa chữa đầy đủ.
Triệu chứng liên quan
Khi tháo battery, vòng ly hợp bị kẹt vật lý, nứt, quá lỏng hoặc không thể căn chỉnh cài đặt số hoặc chế độ khoan với dấu chỉ.
Khi tháo battery, vòng cổ ly hợp bị kẹt vật lý, 1. Tháo battery trước khi quay hoặc kiểm tra vòng cổ chế độ/mô-men xoắn.