failure mode
FM-07: FM-07 LADDNING STARTAR ELLER STOPPAR NÄR BATTERY FLYTTAS ELLER HÅLLS
Laddning startar eller stoppar intermittent när battery flyttas eller hålls i vissa positioner på grund av instabil kontakt eller ljusbågar.
Diagnostisk översikt
Laddning startar eller stoppar intermittent när battery flyttas eller hålls i vissa positioner på grund av instabil kontakt eller ljusbågar.
Troliga grundorsaker
- The insertion stem, guide surfaces, or seating stops are worn, dirty, or distorted
- Battery contacts are recessed, contaminated, loose, or damaged
- The charger contact carrier or slot is damaged
- The release tabs or seating geometry do not hold the electrical interface
- An internal battery terminal link is movement-sensitive
Snabbkontroller
- Charging remains stable without hand pressure or movement, or the unstable interface is isolated to the pack or charger.
Reparationsförhandsgranskning
- Stop wiggling the battery, unplug the charger, and remove the pack so arcing or repeated contact interruption cannot continue.
- 1.
Det här är en förhandsgranskning av felsökningsvägledningen i den fullständiga reparationsmanualen.
Relaterade symtom
Laddning startar eller stoppar när battery flyttas eller hålls
flyttades, lyftes eller hölls i en position. FM-07
Laddarens indikation eller laddningscykel ändras när det insatta battery rörs, flyttas, lyfts eller hålls i en position.
Laddarens indikation eller laddningscykel ändras när det isatta battery berörs, 1. Sluta skaka battery, koppla ur laddaren och ta bort paketet så att ljusbåge eller