failure mode
FM-11: Het werklicht werkt niet normaal
De werklamp is donker of flikkert, of de vertraging na het loslaten van de trekker is abnormaal.
Diagnostisch overzicht
De werklamp is donker of flikkert, of de vertraging na het loslaten van de trekker is abnormaal.
Waarschijnlijke grondoorzaken
- Battery charge is too low for a valid test
- Trigger is not moving far enough to activate the light
- Lens area is blocked by dry debris
- LED or wiring is damaged
- Switch or electronic control fault
Snelle controles
- The worklight activates with the trigger and turns off after normal delay.
Reparatievoorvertoning
- Remove the saw from the work and install a charged known-good battery.
- Operate lock-off and trigger briefly while watching the light.
- Brush only loose dry debris from the lens area and repeat the no-load timing check.
- If the light stays dark, flickers, or times incorrectly, use qualified service.
Dit is een voorvertoning van de probleemoplossingsgids in de volledige reparatiehandleiding.
Veelvoorkomende oplossingen
- Werklicht en lens
- Werklicht, behuizing of geleiders
Gerelateerde symptomen
Het werklicht werkt niet normaal
De werklamp is donker of flikkert, of de vertraging na het loslaten van de trekker is abnormaal.
Inbegrepen in de volledige handleiding
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views
- post-repair checks
Openbare pagina's tonen alleen een voorvertoning. Koop de volledige handleiding om complete reparatiestappen, diagrammen en verificatieprocedures te downloaden.