failure mode
FM-19: FM-19 MOTOR RUNS, BUT THE CHUCK AND ANVIL DO NOT ROTATE
FM-19 MOTOR RUNS, BUT THE CHUCK AND ANVIL DO NOT ROTATE
Diagnostisk oversikt
FM-19 MOTOR RUNS, BUT THE CHUCK AND ANVIL DO NOT ROTATE
Sannsynlige rotårsaker
- Gear or motor pinion connection has failed
- Impact hammer or anvil is broken or disconnected
- Internal bearing or drive part is jammed
- Severe wear has stripped the transmission path
Raske kontroller
- Motor rotation is transmitted to a stable rotating anvil, or the tool is removed for service.
Reparasjonsforhåndsvisning
1.
Dette er en forhåndsvisning av feilsøkingsveiledningen som er inkludert i den fullstendige reparasjonsmanualen.
Relaterte symptomer
The motor can be heard, but the front output remains still in both directions with the bit removed.
The motor can be heard, but the front output remains 1. Release the trigger, remove the battery, and remove the bit if it can be done
Inkludert i den fullstendige manualen
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views