failure mode
FM-21: 0도 절단이 재료를 직각으로 통과하지 않습니다
베벨 포인터가 0으로 설정되고 슈가 평평해 보여도 완성된 절단이 작업 표면에 대해 일관되게 90도가 아닙니다.
진단 개요
베벨 포인터가 0으로 설정되고 슈가 평평해 보여도 완성된 절단이 작업 표면에 대해 일관되게 90도가 아닙니다.
예상 근본 원인
- Zero-degree shoe calibration is out of adjustment
- Bevel lever is not fully locked or shoe moves during the cut
- Blade is bent, loose, or side-loaded
- Shoe is bent, dirty, or not resting flat on the work
빠른 점검
- An actual zero-bevel scrap cut measures square through the material and the locked setting repeats.
수리 미리보기
- Release the trigger, wait for a full stop, remove the battery, set bevel to zero, and clean the shoe/blade reference surfaces.
- Confirm a straight correctly clamped blade, a flat undamaged shoe, and a bevel lever that locks without movement.
- Retract the lower guard with the battery removed, place the saw on its blade side, and compare the blade plate - not a tooth - to an accurate square agains
- Adjust only the accessible 90-degree calibration screw by the official procedure, relock the bevel lever, and return the guard to normal operation.
- - Make and square-check an actual supported scrap cut - if the setting will not calibrate or hold, stop and route the shoe, quadrant, pivot, and spindle align
이것은 전체 수리 매뉴얼에 포함된 문제 해결 안내의 미리보기입니다.
일반적인 수리
- 베벨 레버, 쿼드런트, 포인터 및 제로 보정
- 슈 및 구조 피벗
- 하부 블레이드 가드, 후퇴 레버, 피벗 및 스프링
- 기어케이스, 기어, 베어링 또는 스핀들
- 기어케이스, 기어, 베어링 및 스핀들
- 7-1/4인치 목재 절단 블레이드
관련 증상
0도 절단이 재료를 직각으로 통과하지 않습니다
베벨 포인터가 0으로 설정되고 슈가 평평해 보여도 완성된 절단이 작업 표면에 대해 일관되게 90도가 아닙니다.
전체 매뉴얼에 포함
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views
- post-repair checks
공개 페이지에는 미리보기만 표시됩니다. 전체 수리 단계, 다이어그램 및 검증 절차를 다운로드하려면 전체 매뉴얼을 구매하세요.