failure mode
FM-10: Motorは停止するが、電気ブレーキがブレードの慣性を減らさなくなる
トリガーを離すとmotorの音は止まるが、ブレードは以前よりもはるかに長く慣性で回り続けます。
診断の概要
トリガーを離すとmotorの音は止まるが、ブレードは以前よりもはるかに長く慣性で回り続けます。
考えられる根本原因
- Electric-brake control or motor feedback has failed
- Battery connection is intermittent during deceleration
- Blade, washer, or spindle condition is affecting coast behavior
- Expectation is based on an instant stop rather than a measurable change from normal operation
簡単チェック
- The product has an electric brake, but no owner procedure establishes an exact stop time. Always wait for a complete stop and guard closure regardless of brake behavior. Trigger release ends motor power and the repaired brake consistently shortens blade coast without noise, runout, or guard contact.
修理プレビュー
- - Keep the shoe supported and hands on the handles until the blade stops completely and the lower guard closes - do not set the saw down during the coast.
- Remove the battery and verify that the blade, clamp washer, screw, and lower guard are correctly assembled and free of visible damage or drag.
- Fit a known-good fully charged compatible pack and make several clear no-load stop comparisons without contacting wood.
- If the motor command ends but braking is consistently absent compared with the saw's established normal behavior, stop use and request authorized brake, mo
これは完全修理マニュアルに含まれているトラブルシューティングガイダンスのプレビューです。
一般的な修理方法
- ギアケース、ギア、ベアリング、スピンドル
- 7-1/4インチ木材切断用ブレード
- 下部ブレードガード、引き込みレバー、ピボット、スプリング
- 電子moduleまたはブラシレスmotor
- 電子module、ブラシレスmotor、電気ブレーキ
関連する症状
Motorは停止するが、電気ブレーキがブレードの慣性を減らさなくなる
トリガーを離すとmotorの音は止まるが、ブレードは以前よりもはるかに長く慣性で回り続けます。