failure mode
FM-12: ブレードBOLTまたはスピンドルロックが作動しない
FM-12 ブレードBOLTまたはスピンドルロックが作動しない問題。
診断の概要
FM-12 ブレードBOLTまたはスピンドルロックが作動しない問題。
考えられる根本原因
- Lock is not aligned with the spindle position
- Left-hand bolt is being turned the wrong direction
- Hex recess or wrench is rounded
- Bolt, washer, or spindle threads are dirty or damaged
- Spindle lock mechanism is broken
簡単チェック
- The spindle lock engages only while stopped, the bolt turns in the correct direction, and the blade clamps securely.
修理プレビュー
- Clean the bolt, washer, and accessible spindle seating dry and inspect for cross-threading, cracks, burrs, or incorrect hardware.
- If the lock will not engage or the bolt is seized, stripped, or damaged, do not improvise leverage; have the spindle and hardware serviced.
- Remove the battery, use the supplied hex wrench, and press the spindle lock while rotating the blade by hand until the lock fully engages.
- Remember the left-hand thread: turn the blade bolt clockwise to loosen and counterclockwise to tighten; stop if the wrench or recess begins to round.
これは完全修理マニュアルに含まれているトラブルシューティングガイダンスのプレビューです。
関連する症状
スピンドルロックが作動せず、付属のレンチでboltが回せない、またはブレードboltが固着、損傷、またはねじ山が潰れている。
スピンドルロックが作動せず、付属のレンチでbatteryを回せず、ブレードの{PART_NAME:1}が固着、摩耗、またはクロススレッドしている。1. batteryを取り外し、付属の六角レンチを使用し、スピンドルロックを押しながら手でブレードを回してロックが完全にかかるまで操作する。