failure mode
FM-01: Gergaji Mati Total - Tidak Ada Lampu Kerja dan Tidak Ada Respon Motor
battery yang terlihat terisi terpasang dan pemicu ditarik, tetapi lampu kerja tidak menyala dan mata pisau tidak bergerak.
Diagnostic overview
battery yang terlihat terisi terpasang dan pemicu ditarik, tetapi lampu kerja tidak menyala dan mata pisau tidak bergerak.
Likely Root Causes
- FLEXVOLT battery is discharged, protected, damaged, or not fully seated
- Battery rails or accessible contacts are dirty, wet, burned, or damaged
- Trigger lock-off is not being released
- Trigger switch, electronic module, motor, or internal power path has failed
Quick Checks
- With a proven pack installed, the worklight responds to trigger operation and the blade reaches normal no-load speed.
Repair Preview
- Set the saw on its side with the trigger released, remove the battery, and keep the blade clear of people and material.
- - Inspect the pack, rails, latch, and accessible contacts for cracks, swelling, liquid, scorching, unusual heat, or debris - route any battery hazard to FM-06
- Charge the pack with its designated charger, clean only dry accessible interfaces, and install a known-good fully charged compatible FLEXVOLT pack until it
- - Press the lock-off deliberately and pull the trigger once with the blade clear of all material - if the worklight and motor both remain absent, keep the hou
This is a preview of the troubleshooting guidance included in the full repair manual.
Common Fixes
- Modul elektronik module atau brushless motor
- Lampu kerja dan lensa
- Paket battery FLEXVOLT
- Rel, kontak, kait, dan pelepas Battery
- Kunci pemicu dan saklar pemicu
- Modul elektronik module, motor brushless, dan rem listrik
Related symptoms
Gergaji Mati Total - Tidak Ada Lampu Kerja dan Tidak Ada Respon Motor
battery yang terlihat terisi terpasang dan pemicu ditarik, tetapi lampu kerja tidak menyala dan mata pisau tidak bergerak.