failure mode
FM-07: Le protecteur inférieur de la lame ne se rétracte pas ou ne se ferme pas librement
Le protège-lame inférieur se coince, bouge lentement, frotte, reste ouvert ou ne couvre pas la lame.
Aperçu diagnostique
Le protège-lame inférieur se coince, bouge lentement, frotte, reste ouvert ou ne couvre pas la lame.
Causes probables
- Sawdust or chips obstruct the guard path
- Guard is bent, cracked, or misassembled
- Retracting lever, pivot, or spring is damaged
- Blade or clamp parts rub the guard at some angles or depths
- Guard mechanism requires qualified adjustment or replacement
Vérifications rapides
- The lower guard moves freely and closes promptly over the blade.
Aperçu de réparation
- Remove the battery and move the guard only with its retracting lever.
- Check free travel and prompt spring closing through all bevel and depth settings.
- Brush sawdust from the guard and clamp area, and confirm no blade or washer contact.
- - If the guard is slow, damaged, missing, or will not close, do not use the saw - seek service.
Ceci est un aperçu des conseils de dépannage inclus dans le manuel de réparation complet.
Réparations courantes
- Protège-lame inférieur et levier de rétraction
- Mécanisme du protecteur inférieur
Symptômes associés
Le protecteur inférieur de la lame ne se rétracte pas ou ne se ferme pas librement
Le protège-lame inférieur se coince, bouge lentement, frotte, reste ouvert ou ne couvre pas la lame.
Inclus dans le manuel complet
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views
- post-repair checks
Les pages publiques n'affichent qu'un aperçu. Achetez le manuel complet pour télécharger les étapes de réparation, schémas et procédures de vérification complets.