FM-20: DIE KUPPLUNG LÖST NIE AUS UND ÜBERDREHT BEFESTIGUNGEN BEI NIEDRIGEN EINSTELLUNGEN
FM-20
Diagnoseübersicht
FM-20
Wahrscheinliche Ursachen
- Collar is actually in drill mode or a high setting
- Fastener, bit, or scrap material is unsuitable for the comparison
- Clutch cam, spring, or detent is jammed
- Gearbox or spindle bypasses the torque-limiting mechanism
Schnellprüfungen
- The clutch ratchets before overdriving at an appropriate low setting, or the no-release fault is proven.
Reparaturvorschau
- Install a verified battery and drive slowly while holding the tool straight, stopping immediately if the fastener begins to overdrive without ratcheting.
- If several low settings never release under a valid comparison, remove the battery and route the clutch and gearbox to service.
- Remove the battery and set up a matching fastener and sound driver bit in suitable scrap material.
- Set the collar to a low numbered position, use range 1, and confirm the index is not on drill mode.
Dies ist eine Vorschau der Fehlerbehebungsanleitung, die im vollständigen Reparaturhandbuch enthalten ist.
Zugehörige Symptome
Der Kragen bewegt sich und hält eine niedrige nummerierte Einstellung, aber die Kupplung rastet nicht ein, bevor ein Testbefestiger in geeignetem Schrottmaterial überdreht wird.
Der Kragen bewegt sich und hält eine niedrige nummerierte Einstellung, aber die 1. Entfernen Sie das battery und richten Sie ein passendes Befestigungselement und einen einwandfreien Treiberbit in geeignetem Restmaterial ein.