symptom
Bıçak Kayar, Sallanır veya Yanlış Çalışır
Bıçak kayar, merkezden sapar, korumaya sürtünür veya dişleri koruma okuna karşıdır.
Bu belirtinin anlamı
Bıçak kayar, merkezden sapar, korumaya sürtünür veya dişleri koruma okuna karşıdır.
Olası Kök Nedenler
- Blade is mounted in the wrong rotation direction
- Blade size or 5/8 inch arbor hole is incorrect
- Outer washer is reversed or the screw is loose
- Blade is bent, cracked, dirty, or below the required speed rating
- Spindle, clamp washer, bearing, or shoe is damaged
Hızlı Kontroller
- The blade is secure, turns true, and clears the guard at all settings.
Onarım Önizlemesi
- Release the trigger immediately, let the blade stop, and remove the battery.
- - Match teeth to the guard arrow - orient both washers correctly.
- Clean the clamp faces, fit a straight correct blade, and tighten the screw clockwise with the wrench.
- - Hand-turn and no-load test - if wobble, slip, or contact remains, stop and seek service.
Bu, tam onarım kılavuzunda yer alan sorun giderme rehberinin bir önizlemesidir.
İlgili arıza modları
Tam kılavuza dahil
- root cause analysis
- tools needed
- step-by-step repair procedure
- diagrams
- exploded views
- post-repair checks
Herkese açık sayfalar yalnızca önizleme gösterir. Eksiksiz onarım adımları, diyagramlar ve doğrulama prosedürlerini indirmek için tam kılavuzu satın alın.
İlgili belirtiler ve hata kodları
Related models
Common symptoms
- Testere Başlamaz veya Hiçbir Tepki Vermez
- Battery Paketi Oturmaz, Kilitlenmez veya Serbest Bırakılmaz
- Testere Başlar, Sonra Tetik Basılıyken Kesilir
- Bıçak Hızı veya Kesme Kuvveti Normalin Altında
- Tetik veya Kilit Kontrolü Güvenli Çalışmaz
- ELEKTRİKLİ FREN BIÇAĞI HIZLICA DURDURMAZ
- Alt Bıçak Koruyucusu Serbestçe Geri Çekilmez veya Kapanmaz
- Bıçak Çıkarılamaz, Takılamaz veya Sıkılamaz