failure mode
FM-11: ANZEIGE IST DUNKEL, HÄNGT ODER FALSCH, WÄHREND DAS LADEN NORMAL IST
FM-11 ANZEIGE IST DUNKEL, HÄNGT ODER FALSCH, WÄHREND DAS LADEN NORMAL IST
Diagnoseübersicht
FM-11 ANZEIGE IST DUNKEL, HÄNGT ODER FALSCH, WÄHREND DAS LADEN NORMAL IST
Wahrscheinliche Ursachen
- Indicator lens or printed legend is dirty
- Bright ambient light masks the indicator
- LED, lens, or internal indicator connection is failing
- Indicator-control circuit is latched or damaged
Schnellprüfungen
- The indicator clearly matches actual charging and completion, or the charging outcome is normal and the indicator-only fault is routed to service/replacement.
Reparaturvorschau
- If the indicator remains unreliable, stop relying on it and have the complete charger serviced or replaced; do not open the housing.
- Unplug the charger, remove the pack, and clean only the outside of the indicator lens and legend with a dry soft cloth.
Dies ist eine Vorschau der Fehlerbehebungsanleitung, die im vollständigen Reparaturhandbuch enthalten ist.
Zugehörige Symptome
Unabhängige Prüfungen zeigen, dass der battery ein Werkzeug normal lädt und mit Strom versorgt, aber die rote oder gelbe Anzeige zu schwach zum Ablesen ist, festhängt, nach Entfernen des Akkus an bleibt oder nicht dem Etikettenmuster entspricht.
Unabhängige Prüfungen zeigen, dass der battery lädt und Ziehen Sie das Ladegerät aus der Steckdose, entfernen Sie den Akku und reinigen Sie nur die Außenseite der